電流探頭| CT6

更新時間:2024-09-07

產(chǎn)品型號:CT6

產(chǎn)品報價:

產(chǎn)品特點:電流探頭| CT6 Specified rise time and bandwidth are obtained when using the probe cables provided: The P6041 cable used with the CT1 and CT2 is 42 inches nominal. If additional length is required, the ca

CT6電流探頭| CT6的詳細資料:

電流探頭| CT6

電流探頭| CT6

Features & Benefits

  • High Bandwidth
  • Ultra-low Inductance
  • Very Small Form Factor
  • Characterize Current Waveforms up to <200 ps Rise Times
  • Very Low Loading of Circuit Under Test
  • Fits Into Dense, Closely-spaced Circuit Designs

Applications

  • Data Storage Read Channel Design
  • Silicon Characterization
  • High-frequency Analog Design
  • ESD Testing
  • Signal Injection
  • Differential Current Measurements
  • Single-shot Low Rep-rate Pulse Measurements
  • Propagation Delay Measurement

CT6 Current Probe

The CT6 is the newest addition to the Tektronix portfolio of high-frequency current probes. It is designed to meet the needs of high-speed circuit design and test applications which require ultra-high bandwidth, low inductance, and extremely small form factor. The CT6 provides up to 2 GHz bandwidth when used with high-bandwidth oscilloscopes such as the Tektronix TDS694C, TDS794D, and TDS7000 Series oscilloscopes or with other compatible 50 Ω input measuring instruments. Low inductance (<3 nH) assures that the loading effect of the CT6 on the circuit-under-test will be negligible, which is especially important for today's low-amplitude, high-speed circuit designs such as disk drive read/write preamplifiers. The probe is a closed-circuit design which will accept uninsulated wire sized up to 20 gauge. This product is exempt from CE mark by virtue of its 30 V voltage limit.

CT1/CT2 Current Probes

The CT1 and CT2 Current Probes are designed for permanent or semi-permanent in-circuit installation. Each probe consists of a current transformer and an interconnecting cable. The current transformers have a small hole through which a current carrying conductor is passed during circuit assembly.

The P6041 Probe Cable provides the connection between the CT1 and CT2 Current Transformers and a BNC oscilloscope input. A 50 Ω termination is required to terminate the cable when connected to a high-impedance (1 MΩ) oscilloscope input. One probe cable can be used to monitor several current transformers that have been wired into a circuit.


CT1/CT2. Current Probes with P6041 BNC Probe Cable.

 

Miniature Construction

The CT1 and CT2 detachable cable design enables one or more probes to be located on circuit boards or in other limited space areas.

The CT6 offers the smallest form factor available, for measurement on ever-shrinking circuit boards and components. It is designed for temporary installation and does not incorporate removable cables, as the CT1 and CT2 do.

Extendible Probe Length

Specified rise time and bandwidth are obtained when using the probe cables provided: The P6041 cable used with the CT1 and CT2 is 42 inches nominal. If additional length is required, the cables can be extended by using high-quality 50 Ω cable and suitable interface connectors. (Also see Special Probe Cables, Optional Accessories.) Long cables may degrade high-frequency response.

High Sensitivity

The CT1 and CT6 provide an output of 5 mV for each milliamp of input current when terminated in 50 Ω. The CT2 provides 1 mV per milliamp when terminated in 50 Ω.

Typical Systems

The CT1, CT2, and CT6 high-frequency current transformers are dynamic (i.e., non-DC) current measuring devices. They are typically used in conjunction with compatible high-bandwidth oscilloscopes and other instruments to observe and/or record high-frequency current waveforms. The CT1, CT2, and CT6 normally operate directly into 50 Ω scopes and other measuring device inputs.

The CT1 or CT2 can be used with 1 MΩ input systems; use the P6041 probe cable and terminate the output with a 50 Ω feed-through termination (see Optional Accessories).

In all cases, the CT1, CT2, and CT6 must work into 50 Ωs to obtain specified performance and sensitivity.

 

 如果你對CT6電流探頭| CT6感興趣,想了解更詳細的產(chǎn)品信息,填寫下表直接與廠家聯(lián)系:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

滬公網(wǎng)安備 31011402002799號

中文字幕在线观看三区五区| 日本人妻一区二区三区不卡影院| 久久久精品一区二区三三级片| 888午夜不卡| 人妻无码第17页| 国产精品美女自在线| 成人黄色大香蕉| 97se狠狠狠狼鲁亚洲综合| 射一射日一日射| 亚洲欧美日韩中文字幕二区三区| 私库av不卡一区二区| aaa级国产欧美| 欧美大胆自拍一区| 在线国产不卡五月天| 欧美久久综合网一区二区| 98国产欧美视频| 国内精品久久久久久无码不卡| 好看欧美精品五区| 囗交双飞深喉吞精XXX一区二区| 四川人日逼视频| 香港大香蕉伊仁| 亚洲图片之自拍偷拍拍| 久久e热这里这只有精品12| 日韩视频一区二区三区| 色逼总和网| 美女张开双腿在线播放中文| 日韩黄片精品在线| 无码电影网站免费| 国产亚洲精品色欲在线观看| 色五月+亚+洲| 麻豆国产电影在线| 日韩人妻一区二区三| 久久人妻中文字幕视频| 少妇射欧美| 日本三级九九九免费电影| 亚洲精品综合图片| 欧美处女性一区| 亚洲欧美黄色电影在线观看| 在线精品91久久电影| 亚洲区欧美区小说网| 女人又爽 又黄 的视频|